top of page

< Fluid Feedthroughs

Fluid Feedthroughs, thermally insulated_

Fluid Feedthroughs

  • Fluid Feedthroughs

  • Fluid Feedthroughs, thermally insulated

Fluid Feedthroughs, thermally insulated_edited.png
Fluid Feedthroughs
Fluid Feedthroughs, thermally insulated_edited.png

Fluid Feedthroughs

  • Fluid Feedthroughs ISO-KF

  • Fluid Feedthroughs CF

Fluid Feedthroughs ISO-KF.png
Fluid Feedthroughs ISO-KF
Fluid Feedthroughs CF
Fluid Feedthroughs ISO-KF.png

Fluid Feedthroughs ISO-KF

​

Product description

  • Flange material: Stainless steel

​

Subcategories

  • ISO-KF Fluid Feedthrough, Single Tube

  • ISO-KF Fluid Feedthrough, Double Tube

ISO-KF Fluid Feedthrough, Double Tube

​

Technical Data

​

  • Tightness: 1 · 10-11 Pa m³/s

  • Pressure range: 1E-8 hPa – 5E2 hPa over pressure

  • Temperature range (vacuum side): -196 – 300 °C

Connection flange
Vacuum side
Atmosphere side
A [mm]
B [mm]
C [mm]
D [mm]
E [mm]
Part number
Delivery time
DN 40 ISO-KF
P
P
75 mm
45 mm
75 mm
45 mm
6 mm
On Request
DN 40 ISO-KF
S
S
103 mm
73 mm
103 mm
73 mm
6 mm
On Request
DN 40 ISO-KF
V
V
105 mm
75 mm
105 mm
75 mm
6 mm
On Request
Connection flange
Vacuum side
Atmosphere side
A [mm]
B [mm]
C [mm]
Part number
Delivery time
DN 16 ISO-KF
P
P
75 mm
45 mm
6 mm
On Request
DN 16 ISO-KF
S
S
103 mm
73 mm
6 mm
On Request
DN 40 ISO-KF
P
P
75 mm
45 mm
6 mm
On Request
DN 40 ISO-KF
S
S
103 mm
73 mm
6 mm
On Request
DN 40 ISO-KF
V
V
105 mm
75 mm
6 mm
On Request

ISO-KF Fluid Feedthrough, Single Tube

​

Technical Data

​

  • Tightness: 1 · 10-11 Pa m³/s

  • Pressure range: 1E-8 hPa – 5E2 hPa over pressure

  • Temperature range (vacuum side): -196 – 300 °C

Fluid Feedthroughs ISO-KF.png

Fluid Feedthroughs CF

​

Product description

  • Flange material: Stainless steel

​

Subcategories

  • CF Fluid Feedthrough, Single Tube

  • CF Fluid Feedthrough, Double Tube

CF Fluid Feedthrough, Double Tube

​

Technical Data

​

  • Tightness: 1 · 10-11 Pa m³/s

  • Pressure range: 1E-11 hPa – to ambient pressure

  • Temperature range (vacuum side): -196 – 300 °C

Connection flange
Vacuum side
Atmosphere side
A [mm]
B [mm]
C [mm]
D [mm]
E [mm]
Part number
Delivery time
DN 40 CF
P
P
75 mm
45 mm
75 mm
45 mm
6 mm
On Request
DN 40 CF
S
S
103 mm
73 mm
103 mm
73 mm
6 mm
On Request
DN 40 CF
V
V
105 mm
75 mm
105 mm
75 mm
6 mm
On Request
Connection flange
Vacuum side
Atmosphere side
A [mm]
B [mm]
C [mm]
Part number
Delivery time
DN 16 CF
P
P
75 mm
45 mm
6 mm
On Request
DN 16 CF
S
S
73 mm
103 mm
6 mm
On Request
DN 40 CF
P
P
75 mm
45 mm
6 mm
On Request
DN 40 CF
S
S
103 mm
73 mm
6 mm
On Request
DN 40 CF
V
V
105 mm
75 mm
6 mm
On Request

CF Fluid Feedthrough, Single Tube

​

Technical Data

​

  • Tightness: 1 · 10-11 Pa m³/s

  • Pressure range: 1E-11 hPa – to ambient pressure

  • Temperature range (vacuum side): -196 – 300 °C

Fluid Feedthroughs, thermally insulated
Fluid Feedthroughs, thermally insulated_

Fluid Feedthroughs, thermally insulated

  • Fluid Feedthroughs, Thermally insulated ISO-KF

  • Fluid Feedthroughs, Thermally insulated CF

Fluid Feedthroughs, Thermally insulated
Fluid Feedthroughs, Thermally insulated ISO-KF
Fluid Feedthroughs, Thermally insulated

Fluid Feedthroughs, Thermally insulated ISO-KF

​

Product description

  • Flange-tube connection: Thermally insulated tube

  • Flange material: Stainless steel

  • Suitable for liquid nitrogen

​

Subcategories

  • ISO-KF Fluid Feedthrough, Single Tube

  • ISO-KF Fluid Feedthrough, Double Tube

ISO-KF Fluid Feedthrough, Double Tube

​

Technical Data

​

  • Tightness: 1 · 10-11 Pa m³/s

  • Pressure range: 1E-8 hPa – 5E2 hPa over pressure

  • Temperature range (vacuum side): -196 – 300 °C

Connection flange
Vacuum side
Atmosphere side
A [mm]
B [mm]
C [mm]
D [mm]
E [mm]
Part number
Delivery time
DN 40 ISO-KF
P
P
45 mm
75 mm
45 mm
75 mm
6 mm
On Request
DN 40 ISO-KF
S
S
73 mm
103 mm
73 mm
103 mm
6 mm
On Request
DN 40 ISO-KF
V
V
75 mm
105 mm
75 mm
105 mm
6 mm
On Request
Connection flange
Vacuum side
Atmosphere side
A [mm]
B [mm]
C [mm]
Part number
Delivery time
DN 16 ISO-KF
P
P
75 mm
45 mm
6 mm
On Request
DN 16 ISO-KF
S
S
103 mm
73 mm
6 mm
On Request
DN 40 ISO-KF
P
P
75 mm
45 mm
6 mm
On Request
DN 40 ISO-KF
S
S
103 mm
73 mm
6 mm
On Request
DN 40 ISO-KF
V
V
105 mm
75 mm
6 mm
On Request

ISO-KF Fluid Feedthrough, Single Tube

​

Technical Data

​

  • Tightness: 1 · 10-11 Pa m³/s

  • Pressure range: 1E-8 hPa – 5E2 hPa over pressure

  • Temperature range (vacuum side): -196 – 300 °C

Fluid Feedthroughs, Thermally insulated CF
Fluid Feedthroughs, Thermally insulated

Fluid Feedthroughs, Thermally insulated CF

​

Product description

  • Flange-tube connection: Thermally insulated tube

  • Flange material: Stainless steel

  • Suitable for liquid nitrogen

​

Subcategories

  • CF Fluid Feedthrough, Single Tube

  • CF Fluid Feedthrough, Double Tube

CF Fluid Feedthrough, Double Tube

​

Technical Data

​

  • Tightness: 1 · 10-11 Pa m³/s

  • Pressure range: 1E-11 hPa – 1.5E3 hPa over pressure

  • Temperature range (vacuum side): -196 – 300 °C

Connection flange
Vacuum side
Atmosphere side
A [mm]
B [mm]
C [mm]
D [mm]
E [mm]
Part number
Delivery time
DN 40 ISO-KF
P
P
45 mm
75 mm
45 mm
75 mm
6 mm
On Request
DN 40 ISO-KF
S
S
73 mm
103 mm
73 mm
103 mm
6 mm
On Request
DN 40 ISO-KF
V
V
75 mm
105 mm
75 mm
105 mm
6 mm
On Request
Connection flange
Vacuum side
Atmosphere side
A [mm]
B [mm]
C [mm]
Part number
Delivery time
DN 16 ISO-KF
P
P
75 mm
45 mm
6 mm
On Request
DN 16 ISO-KF
S
S
103 mm
73 mm
6 mm
On Request
DN 40 ISO-KF
P
P
75 mm
45 mm
6 mm
On Request
DN 40 ISO-KF
S
S
103 mm
73 mm
6 mm
On Request
DN 40 ISO-KF
V
V
105 mm
75 mm
6 mm
On Request

CF Fluid Feedthrough, Single Tube

​

Technical Data

​

  • Tightness: 1 · 10-11 Pa m³/s

  • Pressure range: 1E-11 hPa – 1.5E3 hPa over pressure

  • Temperature range (vacuum side): -196 – 300 °C

RANVAC

TECHNOLOGIES

INDIA OPERATIONS

RANVAC Technologies

49/3 & 49/4, Thonchinakuppe Village, Nelamangala Taluk,

Bangalore 562123, Karnataka, India

 

sales@ran-vac.com

Tel: +9180505 69933

​

Tel: +9180505 69911

US OPERATIONS

RANVAC Technologies

340, S. Lemon Ave, # 5224

Walnut

California 91789, USA​

​

sales@ran-vac.com

Tel: +1.408 431 8201

CONTACT US

CONTACT

INQUIRES

For any inquiries, questions, or commendations, please fill out the following form

Thanks for submitting!

CUSTOMER FEEDBACK

BLOGSUPPORT | PRIVACY POLICY | GENERAL TERMS OF USE | GENERAL TERMS OF SALE

  • Linkedin

© 2024 RANVAC TECHNOLOGIES, ALL RIGHTS RESERVED

bottom of page